FluoSens Go

Instant measurement. Compact design. Lab-ready.

Plug & Play Fluorescence Measurement in Minutes

FluoSens Go is the fast and flexible solution for labs needing quick, sensitive fluorescence measurements. This compact, easy-to-use device delivers reliable detection of up to 2 fluorophores in surfaces or liquid samples. Ideal for point-of-care testing, R&D labs, and custom setups.

Product Owerview

What Is FluoSens Go?

The FluoSens Go (former ESElog) is a plug‑and‑play fluorescence detector that combines micro-scale LEDs, precision optics, and sensitive sensors in a small form factor. Instantly deployable via USB with onboard calibration, this detector is perfect for rapid assay validation, environmental testing, or mobile workflows.

Key Features

  • USB-powered plug & play – no complex setup required
  • High-sensitivity for low-concentration samples – detect trace-level signals
  • Contact-free measurement – works on liquid samples or surfaces
  • Dual-wavelength capability – detect up to 2 fluorophores simultaneously
  • Compact, portable design – fits into crowded lab benches or mobile carts
  • Built-in calibration and correction – for consistent, reliable readings

Main Benefits

  • Fast Deployment – Begin measurements within minutes
  • No IT or software integration needed – PWM driver + USB interface
  • Versatile Applications – From PCR assays to surface contamination checks
  • Ideal for R&D and field tests – lightweight and easy to transport

Start Measuring Fluorescence Instantly Request a demo or get your FluoSens Go starter kit today.!

Surface and mobile measurements

The confocal measurement principle enables flexible positioning of the detector almost independently of distance and angle. When connected to a small portable personal computer, the FluoSens Go (former ESElog) becomes a fully mobile and compact measurement unit, suitable for use in many situations.

Accessories

The FluoSens Go  Fluorescence Detector is easily customizable for your applications with accessories including:

  • Cuvette or tube holders compatible with optical systems
  • Ready-to-use measurement stations for liquids or solid surfaces
  • Software for measurement (or alternatively labVIEW may be used)

Short time to market

When developing a point-of-need detection system, start your R&D work with a fully developed fluorescence detector. This means you will save costs, speed up your R&D processes, and shorten the time-to-market.

After the initial development phase, you can switch from the ​FluoSens Go to the Fluo Sens Integrated, and simply choose from a wide range of available filter sets, accessories, and customized adaptations to meet almost any measurement need.

FluoSens Go applications

The ​FluoSens Go is a unique fluorescence detector designed for ease of use in a wide range of applications. Direct measurement of liquids or solids can be easily achieved through a small measurement window. The detector comes in a solid housing and can be easily mounted in standard optical benches, such as LINOS or ThorLabs.

The ​FluoSens Go (former ESElog) can be connected to a personal computer via the integrated USB and is compatible with FL Digital Software for routine data evaluation, and labVIEW, for more detailed assessment.

Ordering information

If the wavelength combinations you require are not included in our starter kit, please don’t hesitate to inquire. The table below showcases a variety of combinations we can provide, along with interfaces like RS485 and other accessories, demonstrating both our existing capabilities and potential customizations. For up-to-date licensing information and product-specific disclaimers, see the respective user manual. The user manuals can be requested at customer@dermagnostix.com

ESElog USB Contents Cat. no.
E365/D460/E520/D570 E1/D1: Alexa Fluor 350; Pyrene; Terbium
E2/D2: 5_TAMRATM; Alexa Fluor 532; ATTO 550; Cy3 E1/D2: Qdot 565, evidot 580
9002063
E365/D460/E520/D625 E1/D1: Alexa Fluor 350; Pyrene; Terbium
E2/D2: DY521XL; SYPRO Red
E1/D2: Chlorophyll-a(MeOH); Porphin/Porphyrene
9002064
E365/D460/E520/D680 E1/D1: Alexa Fluor 350; Pyrene; Terbium
E1/D2: Chlorophyll-a(MeOH); Porphin/Porphyrene
9002065
E365/D520/E590/D625 E1/D1: ATTO 390; Cascade YellowTM; Dioxane; GFP; Riboflavin
E2/D2: Alexa Flour 594; ATTO 590; Spectrum Red; Texas Red
E1/D2: Qdot 705
9002066
E365/D625/E660/D720 E1/D1: Europium; Toluene; OEP; tBu4-Azaporphine; Qdot 605
E2/D2: Alexa Flour 660; ATTO 680; Cy 5.5
E1/D2: Qdot 705
9002067
E470/D520/E550/D600 E1/D1: Cy2; FAMTM; FITC; Fluorescein(EtOH); SYBR Green; YFP
E2/D2: BODIPY 564/570; DY-548; Spectrum Orange
E1/D2: RuBpy-NP; SYPRO Ruby
9002068
E470/D520/E565/D625 E1/D1: Cy2; FAM; FITC; Fluorescein(EtOH); SYBR Green; YFP
E2/D2: Alexa Fluor 568; CY3.5; ROXTM; Stains-All
E1/D2: Acid Red 52; SYPRO Tangerine
9002069
E470/D520/E590/D640 E1/D1: Cy2; FAMTM; FITC; Fluorescein(EtOH); SYBR Green; YFP
E2/D2: Oxazine 170; Crystal violet (H2O)
9002070
E470/D520/E660/D720 E1/D1: Cy2; FAM; FITC; Fluorescein(EtOH); SYBR Green; YFP
E2/D2: Oxazine 170; Crystal violet (H2O)
9002071
E470/D550/E590/D660 E1/D1: Acridine Red; Acridine Yellow; Alexa Fluor 430; Auramine
E2/D2: Napthofluoresceine; Sensilight P3
9002072
E470/D570/E625/D680 E1/D1: Phosphine 3R; SensoPath Dye 10; SYPRO Orange
E2/D2: Alexa Fluor 633; Cy5; LIZ; Nile Blue; Spectrum Red
9002073
E470/D570/E625/D720 E1/D1: Phosphine 3R; SensoPath Dye 10; SYPRO Orange
E2/D2: Mg-Phthalocyanine(PrOH, EX625)
9002074